CVE-2026-83549
SonicWall SMA1000 Appliances OS Command Injection Vulnerability
Description
CVE-2026-83549 is a high-severity post-authentication OS command injection vulnerability in the SonicWall SMA1000 Appliance Management Console (AMC). Under specific conditions a remote attacker authenticated as an administrator can execute arbitrary operating system commands on the appliance, resulting in remote code execution beneath the product's own management layer. SMA1000 appliances — SMA6210, SMA7210 and the SMA8200v virtual appliance — are affected before firmware 12.4.3-03526 and, on the 12.5 line, before 12.5.0-02952. The command injection vulnerability carries a CVSS score of 7.8 and an unusually high EPSS score of roughly 8.5% at the 94th percentile, and CISA has added CVE-2026-83549 to the Known Exploited Vulnerabilities (KEV) catalog — it is disclosed alongside the unauthenticated SSRF flaw CVE-2026-83548 in the same SonicWall advisory, and the two chain naturally.
KEV Information
CVSS Score
CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:HOpen in CalculatorAffected Products
| Vendor | Product | Version |
|---|---|---|
| sonicwall | sma8200v | < 12.4.3-03526; >= 12.5.0, < 12.5.0-02952 |
| sonicwall | sma6210 firmware | < 12.4.3-03526; >= 12.5.0, < 12.5.0-02952 |
| sonicwall | sma7210 firmware | < 12.4.3-03526; >= 12.5.0, < 12.5.0-02952 |
References
- https://psirt.global.sonicwall.com/vuln-detail/SNWLID-2026-0016(Vendor Advisory)
- https://www.cisa.gov/known-exploited-vulnerabilities-catalog?field_cve=CVE-2026-83549(US Government Resource)
Weakness Type
CWE-78: Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
OS command injection occurs when software constructs all or part of an operating system command from externally influenced input but fails to neutralise the special elements — shell metacharacters such as ;, |, backticks or $() — that change what the command actually does. In CVE-2026-83549 an administrative function of the SMA1000 Appliance Management Console builds a shell command incorporating input an administrator supplies, so under specific conditions that input escapes its intended argument position and executes arbitrary commands as the appliance process.
Learn more: CWE-78 — Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
Impact Analysis
CVE-2026-83549 is scored with a Local attack vector and low privileges, reflecting that the injection is reached through an authenticated administrative session on the Appliance Management Console rather than by an anonymous internet caller; attack complexity is low and no user interaction is required. The impact is high across confidentiality, integrity and availability: arbitrary OS command execution on an SMA1000 gives access to the appliance's configuration, certificates and stored authentication secrets, allows modification of access policies and the insertion of persistence beneath the management interface, and permits the gateway to be disabled, cutting off remote access for everyone who depends on it. The authentication requirement is less protective than it looks, because SonicWall disclosed this flaw together with CVE-2026-83548, an unauthenticated pre-authentication SSRF in the same appliance — an attacker who first abuses that flaw is well positioned to reach the administrative surface where this one lives. That chaining is the most plausible explanation for the EPSS score of about 8.5% in the 94th percentile, far above what a post-authentication bug would normally attract, and CISA's KEV listing confirms exploitation in the wild.
Exploit Maturity
CISA has confirmed active exploitation of CVE-2026-83549 by adding it to the Known Exploited Vulnerabilities catalog with a remediation deadline of 5 September 2026 that has already passed. The most telling indicator is the EPSS score of roughly 8.5%, in the 94th percentile — an extraordinarily high value for a vulnerability that nominally requires administrator authentication, which strongly suggests attackers are not treating the authentication requirement as a real obstacle, most plausibly because it is chained behind the unauthenticated SSRF CVE-2026-83548 disclosed in the same SonicWall advisory. No public exploit code appears among the available references; the SonicWall PSIRT advisory is the sole vendor source. SonicWall SMA appliances have repeatedly served as initial access for ransomware operations, so any appliance that ran an affected firmware build while reachable warrants a full compromise assessment rather than a patch alone.
Remediation
- Follow the CISA KEV required action immediately. Apply mitigations in accordance with SonicWall's instructions, comply with CISA's BOD 26-04 "Prioritizing Security Updates Based on Risk" guidance and the "Forensics Triage Requirements", and discontinue use of the product if mitigations are unavailable. The KEV due date of 5 September 2026 has passed.
- Upgrade SMA1000 firmware to 12.4.3-03526 or, on the 12.5 line, to 12.5.0-02952 or later. SMA6210, SMA7210 and SMA8200v are all affected below those builds, and the same update addresses the companion pre-authentication SSRF — see SonicWall advisory SNWLID-2026-0016.
- Restrict the Appliance Management Console to a management network. The AMC should never be reachable from the internet or from general user networks; bind it to a dedicated management VLAN or jump-host range so that even an attacker holding administrator credentials cannot reach the vulnerable interface remotely.
- Enforce strong administrative access controls. Rotate all AMC administrator passwords, enable multi-factor authentication for administrative logins, remove unused or shared administrative accounts, and review who legitimately needs AMC access — since the flaw requires an authenticated administrator, reducing the number and exposure of such accounts directly reduces the attack surface.
- Hunt for compromise and harden command construction long term. Inspect the appliance for unexpected processes, files, cron entries and outbound connections, review AMC audit logs for administrative actions that no operator performed, and compare the configuration against a trusted baseline; then apply the general defence for this weakness class — avoid invoking shell commands from application code at all, and where unavoidable pass arguments as separate array elements through APIs that never interpret shell metacharacters.
Technical Details
CVE-2026-83549 is an OS command injection flaw (CWE-78) in the SonicWall SMA1000 Appliance Management Console. A management function constructs an operating system command that incorporates externally influenced input available to an authenticated administrator, and under specific conditions the special elements in that input are not neutralised, so the shell interprets them as command syntax rather than as data. The result is execution of arbitrary commands in the security context of the appliance process, which on a hardened network appliance is typically a highly privileged account with access to configuration stores and certificate material. The CVSS vector CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H records a local attack vector with low privileges, low complexity and no user interaction, and complete impact on confidentiality, integrity and availability at unchanged scope; the "Local" vector expresses that the attacker operates through an established administrative session on the console rather than through an anonymous network request. In practice the flaw functions as a privilege escalation from appliance administrator to arbitrary code beneath the management abstraction, which is what makes it valuable as the second stage of a chain that begins with the unauthenticated SSRF disclosed in the same advisory.
Frequently Asked Questions
Is CVE-2026-83549 being actively exploited?
Yes. CISA added CVE-2026-83549 to its Known Exploited Vulnerabilities catalog with a remediation due date of 5 September 2026, confirming exploitation in the wild. Its EPSS score of about 8.5% places it in the 94th percentile, which is remarkably high for a post-authentication flaw and suggests it is being chained with the unauthenticated SSRF disclosed in the same advisory.
What products are affected by CVE-2026-83549?
SonicWall SMA1000 appliances are affected — the SMA6210 and SMA7210 hardware appliances and the SMA8200v virtual appliance — in firmware before 12.4.3-03526 and, on the 12.5 line, before 12.5.0-02952. The vulnerable component is the Appliance Management Console (AMC).
How do I fix CVE-2026-83549?
Upgrade SMA1000 firmware to 12.4.3-03526 or 12.5.0-02952 or later per SonicWall advisory SNWLID-2026-0016, which also fixes the companion pre-authentication SSRF. Restrict the Appliance Management Console to a dedicated management network, rotate administrator credentials, enable multi-factor authentication, and audit the appliance for unexpected processes and configuration changes.
How severe is CVE-2026-83549?
CVE-2026-83549 is rated High with a CVSS 3.1 base score of 7.8. It requires an authenticated administrator and a local attack vector rather than anonymous network access, but needs no user interaction and yields arbitrary OS command execution with full confidentiality, integrity and availability impact on a perimeter security appliance; the EPSS score in the 94th percentile and confirmed KEV-listed exploitation make it far more urgent than the base score alone suggests.
Need Help With Vulnerability Management?
Our security experts can help you prioritize and remediate vulnerabilities effectively.