CVE-2026-116606
Barracuda Networks Email Security Gateway (ESG) Authentication Bypass Using an Alternate Path or Channel Vulnerability
Description
CVE-2026-116606 is a critical authentication bypass vulnerability in Barracuda Email Security Gateway (ESG) versions earlier than 9.4.0.030. An unauthenticated remote attacker can invoke a configuration-import function through an alternate path and restore a crafted, compatible backup archive, which results in unauthorized modification of the appliance's global configuration. Because the ESG filters an organization's email at the perimeter, taking over its configuration gives an attacker control over mail flow and security policies. CISA lists CVE-2026-116606 in its Known Exploited Vulnerabilities (KEV) catalog, and its EPSS score of 10.95% places this Barracuda ESG vulnerability in the 96th percentile.
KEV Information
CVSS Score
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:HOpen in CalculatorCWEs
Affected Products
| Vendor | Product | Version |
|---|---|---|
| barracuda | email security gateway 300 firmware | < 9.4.0.030 |
| barracuda | email security gateway 400 firmware | < 9.4.0.030 |
| barracuda | email security gateway 600 firmware | < 9.4.0.030 |
| barracuda | email security gateway 800 firmware | < 9.4.0.030 |
| barracuda | email security gateway 900 firmware | < 9.4.0.030 |
References
- https://github.com/mandiant/Vulnerability-Disclosures/blob/master/2026/MNDT-2026-0042.md(Third Party Advisory)
- https://trust.barracuda.com/security/pre-authentication-authorization-bypass-command-injection(Vendor Advisory)
- https://www.cisa.gov/known-exploited-vulnerabilities-catalog?field_cve=CVE-2026-116606(US Government Resource)
Weakness Type
CWE-288: Authentication Bypass Using an Alternate Path or Channel
This weakness occurs when a system that requires authentication can be reached through an alternate entry point that does not enforce the same checks. In CVE-2026-116606, the configuration-import function of the Barracuda Email Security Gateway is reachable without authentication, so an attacker can bypass the login of the administration interface entirely and restore an attacker-controlled backup.
Learn more: CWE-288 — Authentication Bypass Using an Alternate Path or Channel
Impact Analysis
CVE-2026-116606 has the CVSS v3.1 base score 9.8 (CRITICAL). It is remotely exploitable without physical access, easy to exploit with no special conditions, requires no authentication and no user action. Confidentiality, Integrity and Availability are all rated High: by importing a crafted backup, an attacker can replace the global configuration, for example to reroute or copy mail, weaken filtering, create administrator access or disrupt mail delivery for the entire organization. Confirmed exploitation in the CISA KEV catalog and a 96th-percentile EPSS score show that exposed ESG appliances are under real attack.
Exploit Maturity
CISA has confirmed active exploitation in the wild by adding CVE-2026-116606 to the KEV catalog on November 10, 2026, with a due date of November 13, 2026; ransomware usage is not known. The EPSS score of 10.95% (96th percentile) indicates a high likelihood of exploitation compared to other vulnerabilities. Technical details are documented in the Mandiant disclosure MNDT-2026-0042. Barracuda covers this issue in the same advisory as CVE-2026-111560, an OS command injection that requires administrator privileges; chaining the two would let an unauthenticated attacker progress from configuration takeover to root command execution on the appliance.
Remediation
- Patch immediately: Follow the KEV required action to "apply mitigations in accordance with vendor instructions" as described in the Barracuda security advisory; the CISA due date was November 13, 2026.
- Update to 9.4.0.030 or later: All Barracuda Email Security Gateway 300, 400, 600, 800 and 900 firmware versions before 9.4.0.030 are affected; this version also includes the fix for CVE-2026-111560.
- Block access to the administration interface: Make sure the ESG management interface is not reachable from the internet and is restricted to a management network or VPN.
- Verify configuration integrity: Compare the current global configuration with a known-good baseline, check for unexpected administrator accounts, relay or forwarding rules, disabled filters and recent configuration imports in the logs; treat any unexplained change as an incident.
- Respond to suspected compromise: If tampering is found, rebuild the configuration from a trusted backup, rotate all credentials and keys stored on the appliance, and review mail logs for exfiltrated or rerouted messages.
Technical Details
CVE-2026-116606 is a CWE-288 flaw: the configuration-import function of the Barracuda Email Security Gateway can be invoked through a path that does not enforce the authentication applied to the regular administration interface. An attacker supplies a crafted backup archive that is compatible with the appliance's import format, and the ESG restores it, overwriting its global configuration with attacker-controlled settings. Since configuration import is a privileged administrative operation, this effectively grants administrator-level control without credentials. The CVSS v3.1 vector CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H reflects an unauthenticated network attack of low complexity without user interaction that fully compromises the appliance.
Frequently Asked Questions
Is CVE-2026-116606 being actively exploited?
Yes. CISA added CVE-2026-116606 to the Known Exploited Vulnerabilities catalog on November 10, 2026, with a due date of November 13, 2026. The EPSS score of 10.95% is in the 96th percentile; ransomware usage is not known.
What products are affected by CVE-2026-116606?
Barracuda Email Security Gateway 300, 400, 600, 800 and 900 firmware versions earlier than 9.4.0.030 are affected. Version 9.4.0.030 and later contain the fix.
How do I fix CVE-2026-116606?
Update the Barracuda Email Security Gateway to firmware 9.4.0.030 or later and make sure its administration interface is not reachable from the internet. Then verify the global configuration against a known-good baseline to rule out prior tampering.
How severe is CVE-2026-116606?
CVE-2026-116606 is rated 9.8 (CRITICAL) under CVSS v3.1 because an unauthenticated attacker can take over the appliance configuration remotely. Confirmed exploitation, a 96th-percentile EPSS score and possible chaining with CVE-2026-111560 make it an emergency patch.
Need Help With Vulnerability Management?
Our security experts can help you prioritize and remediate vulnerabilities effectively.