CVE-2026-110936

MEDIUM(6.7)KEV

Siemens Software Center Uncontrolled Search Path Element Vulnerability

Description

CVE-2026-110936 is an uncontrolled search path element vulnerability in Siemens Software Center, the deployment and update client Siemens ships with its industrial software portfolio. All versions before V4.0.9.8 load dynamic-link libraries (DLLs) from a search path that an attacker can influence, so an authenticated local attacker who can write into one of the searched directories can place a crafted DLL there and have it executed with the privileges of Siemens Software Center. This DLL hijacking vulnerability turns write access to a directory into arbitrary code execution on engineering workstations that typically sit close to production systems. Siemens has published a dedicated notice about active exploitation of CVE-2026-110936, and CISA has added it to the Known Exploited Vulnerabilities catalog with a remediation deadline of November 3, 2026.

KEV Information

Vendor
Siemens
Product
Software Center
Date Added
October 20, 2026
Due Date
November 3, 2026
Required Action
Apply mitigations in accordance with vendor instructions, ensuring compliance with CISA’s BOD 26-04 Prioritizing Security Updates Based on Risk (see URL in Notes) guidance and CISA’s “Forensics Triage Requirements” (see URL in Notes). Follow applicable BOD 26-04 guidance for cloud services or discontinue use of the product if mitigations are unavailable. Stakeholders are responsible for evaluating each asset's internet exposure and ensuring adherence to BOD 26-04 patching guidelines.

CVSS Score

Vector String
CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:HOpen in Calculator
Attack Vector
LOCAL
Attack Complexity
LOW
Privileges Required
HIGH
User Interaction
NONE
Scope
UNCHANGED
Confidentiality Impact
HIGH
Integrity Impact
HIGH
Availability Impact
HIGH
Exploitability Score
0.8
Impact Score
5.9

CWEs

Affected Products

VendorProductVersion
siemenssoftware center< 4.0.9.8

References

Weakness Type

CWE-427: Uncontrolled Search Path Element

An uncontrolled search path element exists when a program resolves a library or resource through a search path in which one or more directories can be controlled by an unintended party. In Siemens Software Center, the application searches for DLLs in directories that an authenticated local user may be able to write to, so a malicious DLL placed in such a directory is found before — or instead of — the legitimate one and is loaded into the application's process.

Learn more: CWE-427 — Uncontrolled Search Path Element

Impact Analysis

CVE-2026-110936 carries a CVSS 3.1 base score of 6.7 (Medium) with the vector CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H. Attack Vector (Local) and Privileges Required (High) are what hold the score down: the attacker must already be authenticated on the machine and must be able to write to a directory in the search path, which usually means an administrative or otherwise elevated context. Attack Complexity (Low) and no user interaction mean that once the DLL is in place, the next start of Siemens Software Center loads it deterministically. Confidentiality, Integrity and Availability (all High): the injected code runs inside the application and inherits its privileges, giving the attacker the data the application can read, the ability to tamper with software deployments it manages, and the ability to disable it. The real weight of this vulnerability lies in where Siemens Software Center runs — engineering and operator workstations in industrial environments — and in the fact that an application used to distribute software is an ideal position from which to reach further systems. The EPSS score of 0.14% is very low, but Siemens itself has published a notice about active exploitation, so the statistical estimate should not drive the priority here.

Exploit Maturity

Siemens ProductCERT has published a dedicated advisory about active exploitation of CVE-2026-110936 in Siemens Software Center, and CISA has added the vulnerability to the Known Exploited Vulnerabilities catalog, so exploitation in the wild is confirmed from both the vendor and the government side; the KEV entry does not flag ransomware usage. The reference set contains vendor advisories rather than exploit code, so no public proof-of-concept is listed, which is unsurprising for a DLL hijack: the technique is generic and well understood, and the only vulnerability-specific knowledge an attacker needs is which directory the application searches. The EPSS score of 0.14% (3rd percentile) is close to the bottom of the scale and is a poor guide here, because EPSS models internet-facing, remotely scannable exploitation and this is a local privilege-and-persistence technique used after initial access. For industrial operators, the correct reading is that this flaw is being used in targeted intrusions, not that it is unlikely to be attacked.

Remediation

  1. Carry out the action CISA requires. Apply mitigations in accordance with Siemens' instructions, comply with CISA's BOD 26-04 "Prioritizing Security Updates Based on Risk" guidance and the "Forensics Triage Requirements", and discontinue use of the product if mitigations are unavailable. The KEV remediation deadline is November 3, 2026.
  2. Update Siemens Software Center to V4.0.9.8 or later. Every version below V4.0.9.8 is affected. The fix and any interim measures are documented in Siemens Security Advisory SSA-580366 and in the Siemens ProductCERT notice on active exploitation of CVE-2026-110936.
  3. Remove write access from directories in the DLL search path. Audit the installation directory and any other directory the application searches, ensure that standard users cannot create or replace files there, and pay particular attention to world-writable paths and to directories added to the system PATH by third-party installers.
  4. Hunt for planted DLLs and prior execution. Compare the DLLs present in and around the installation directory against the vendor's file list, check creation and modification timestamps for files that do not belong to an official installation, and review Windows event logs and EDR telemetry for unexpected modules loaded into the Siemens Software Center process.
  5. Harden against DLL hijacking as a class. Keep writable application data separate from directories from which code is loaded, prefer absolute paths for library loading, and apply the Windows mitigations that CWE-427 calls for — SetDllDirectory("") and LOAD_LIBRARY_SEARCH_SYSTEM32 — in software you control, combined with application allowlisting on engineering workstations.

Technical Details

Siemens Software Center resolves DLL dependencies through a search path whose elements are not fully under the application's control, which is the defining condition of CWE-427. When Windows resolves a module name, it walks the search order directory by directory and loads the first match; if any directory ahead of the legitimate one is writable by an authenticated local user, a crafted DLL placed there wins the lookup. Because the loader executes the library's entry point as part of the load, the attacker's code runs inside the Siemens Software Center process before the application's own logic can inspect anything. The CVSS vector CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H describes exactly this shape: local access with high privileges is the precondition, the exploitation itself is deterministic and requires no victim interaction, and the impact is total within an unchanged scope, since the attacker gains the full authority of the affected application rather than crossing into another security authority.

Frequently Asked Questions

Is CVE-2026-110936 being actively exploited?

Yes. Siemens ProductCERT published a notice on October 19, 2026 about active exploitation of CVE-2026-110936 in Siemens Software Center, and CISA has added it to the Known Exploited Vulnerabilities catalog with a remediation deadline of November 3, 2026. Use in ransomware campaigns is not recorded, and the EPSS score of 0.14% is low because EPSS measures remotely observable exploitation, which does not apply to a local DLL hijack.

What products are affected by CVE-2026-110936?

CVE-2026-110936 affects Siemens Software Center in all versions below V4.0.9.8. Siemens Software Center is the client used to install and update Siemens software products, so the vulnerability typically sits on engineering and operator workstations rather than on servers. Version V4.0.9.8 and later contain the fix.

How do I fix CVE-2026-110936?

Update Siemens Software Center to V4.0.9.8 or later as described in Siemens Security Advisory SSA-580366. Until the update is deployed, remove write permissions for non-administrative users from the application's installation directory and every other directory in its DLL search path, and check those directories for DLLs that are not part of the official installation.

How severe is CVE-2026-110936?

CVE-2026-110936 is rated Medium with a CVSS 3.1 base score of 6.7. The impact itself is severe — arbitrary code execution with full loss of confidentiality, integrity and availability within the application — but the requirement for local access with high privileges keeps the base score in the medium range. Its EPSS score of 0.14% sits in the 3rd percentile, yet confirmed exploitation reported by both Siemens and CISA makes this a high-priority patch for industrial environments.

CVSS Score

6.7
MEDIUM(6.7)

EPSS Score

EPSS Score0.97%
EPSS Percentile62.3%

Dates

PublishedOctober 15, 2026
Last ModifiedOctober 21, 2026
StatusAnalyzed
CVSS Versionv3.1

Need Help With Vulnerability Management?